The BEP-M300F Benchtop Multi-parameter Analyzer adopts a multi-purpose measurement method, which is suitable for the fields of health disease control, environmental protection, biological agriculture and forestry, water quality analysis, scientific research and institutions of higher learning.
General Features
pH
Ion
Conductivity
DO
| Model | BEP-M300F | |
| Parameters | pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) | |
| pH | Range | -2.00 to 20.00pH |
| Resolution | 0.1, 0.01 pH | |
| Accuracy | ±0.01 pH | |
| Calibration Points | Up to 5 | |
| Standard Customization | Yes | |
| Standard Recognition | NIST, GB and DIN buffers | |
| Slope Limit | Yes | |
| mV | Range | -2000.0 to 2000.0 mV |
| Resolution | 0.1 mV | |
| Accuracy | ±0.3 mV or ±0.1% | |
| pX | Range | -2.00 to 20.00 |
| Resolution | 0.1, 0.01 pX | |
| Accuracy | ±0.01 pX | |
| Calibration Points | Up to 5 | |
| ISE | Range | 1E-9 to 9.999E9 |
| Unit | mol/L, mmol/L, g/L, mg/L, μg/L, ppm | |
| Resolution | Up to 4 significant digits | |
| Accuracy | ±0.5% | |
| Calibration Points | Up to 5 | |
| Conductivity | Range | 0.000 μS/cm to 1000 mS/cm |
| Resolution | 0.001 μS/cm minimum, | |
| various with range selection | ||
| Accuracy | ±1.0% FS | |
| Reference Temperature | 20, 25 ºC | |
| Calibration Points | Up to 3 | |
| Standard Recognition | 84μS/cm, 1413μS/cm, 12.88mS/cm | |
| Resistivity | Range | 5.00 Ω·cm~20.00 MΩ·cm |
| Resolution | 0.01 Ω·cm minimum | |
| Accuracy | ±1.0% FS | |
| TDS | Range | 0.00ppm~300ppt |
| Resolution | 0.01mg/L minimum, various with range selection | |
| Accuracy | ±1.0% FS | |
| Salinity | Range | 0.0~80.0ppt |
| Resolution | 0.1ppt | |
| Accuracy | ±2ppt | |
| Dissolved Oxygen Concentration | Range | 0.00 to 20.00 ppm |
| Resolution | 0.01ppm | |
| Accuracy | ±0.10ppm | |
| Calibration Points | Air-saturated water or zero point | |
| Barometric Compensation | Yes | |
| Manual Salinity Factor Correction | Yes | |
| Saturation | Range | (0.0 to 200.0)% |
| Resolution | 0.10% | |
| Accuracy | ±2.0% | |
| Temperature | Range | -5 to 110 ºC, 23 to 230 ºF |
| Unit | ºC, ºF | |
| Resolution | 0.1 | |
| Accuracy | ±0.2 | |
| Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
| Reading Prompts | Reading, Stable, Locked | |
| Temp. Compensation | ATC, MTC | |
| Data management | Data Storage | 500 results each |
| GLP Features | Yes | |
| Inputs | pH Electrode | BNC(Q9) |
| DO with Temp. Probe | 4-pin aviation connector | |
| Conductivity with Temp. Probe | 5-pin aviation connector | |
| Outputs | USB | USB 2.0 flash memory device, PC |
| RS 232 | printer | |
| Display options | Backlight | Yes |
| Auto Shutdown | 1~60 min, off | |
| IP Rating | IP54 | |
| Date and Time | Yes | |
| General | Electricity | AC Adapter, 100-240V AC input, DC9V output |
| Dimensions | 242×195× 68 mm | |
| Weight | 900g | |