Встроенный онлайн- счетчик частиц со встроенным насосом R2100 Br

Счетчик частиц пыли, DPC-J601H

Поток отбора проб: 83 л/мин ±5% (0,1 куб. фут/мин) Размер частиц Канал: 3 мкм, 0,5 мкм, 1 мкм, 3 мкм, 5 мкм, 10 мкм Источник лазерного света: лазерный диод

Под заказ
0 Br
Варианты доставки:
Курьер ~2 дн.
Самовывоз ~3 дн.
Почта ~6 дн.

Свыше 500 товаров

Большой выбор товаров в нашем магазине

Быстрая доставка

Быстрая доставка в любой регион страны

Поддержка клиента

Наши консультанты всегда рады Вам помочь

Description

DPC-J601H Dust Particle Counter is easy to operate and has a friendly human-computer interface. It can conveniently, quickly and effectively detect suspended particles in the purified environment. It is the first choice for pharmaceutical factories and electronics factories to quickly detect the cleanliness of clean rooms.

Features

  1. Imported laser diodes are adopted, with longer life and more stable performance.
  2. Adopt lithium rechargeable battery, stable performance, longer life.
  3. Small in size and easy to carry.
  4. Six-channel particle size display on the same screen, showing particle concentration (particles/m3)
  5. Automatic UCL calculation.

Specifications

Model DPC-J601H
Sampling Flow 2.83L/min ±5% (0.1 CFM)
Particle Size Channel 0.3μm,0.5μm,1μm,3μm,5μm,10μm
Laser Light Source Laser diode
Air Pump Stable continuous work, energy saving and environmental protection
Repeatability Relative Error Under the same measurement conditions, the repeatability of continuous measurement of particle concentration is less than 10%.
Particle Size Distribution Error 0.5μm, 5μm particle size block distribution error ± 10%
Particle Concentration Indication Error After the particle counter is in normal working condition, the particle concentration indication error of the 0.5μm particle size block shall not exceed ±20%FS.
Max. Sampling Concentration 35000 particles/L
Self-Purification Time ≤10min (3 consecutive zero counts within 10min, 95% confidence level)
Sampling Time User-defined (1~14400s)
Sampling Delay User-defined (1~255s)
Sampling Points 2~9
Sampling Times (position) 2~50
Operating Hours After fully charged, it can continuously test for more than 6 hours.
Charging Time 6h
Data Storage Capacity 1~5000 sets of measurement data, which can be queried
Counting Method Cumulative counting
Dimension(L*W*H) 240*135*68mm
N.W./G.W. 0.85kg/4.5kg(with battery)
Shipping Dimension 440*420*240mm