It is used to measure the gas concentration of HC, CO, CO2 and O2 in the exhaust gas of automobiles, automatically calculate and display the air-fuel ratio λ, and comprehensively detect the combustion performance and emission pollution of the engine.
Features
| Model | AEA-H401 |
| Measuring Range | HC:0~10000×10-6(ppm) vol |
| CO: 0~10 ×10-2(%)vol | |
| CO2:0~20×10-2(%)vol | |
| O2: 0~25×10-2(%)vol | |
| λ:0.50~3.00 | |
| COcor:0~10×10-2(%)vol | |
| Indicating Error | HC±12 ×10-6 (ppm) vol (absolute error) or ±5% (relative error) |
| CO±0.06×10-2(%)vol (absolute error)or ±5%(relative error) | |
| CO2 ±0.5×10-2(%)vol (absolute error)or ±5%(relative error) | |
| O2 ±0.1 ×10-2(%)vol (absolute error)or ±5%(relative error) | |
| Stability | Automatic zero calibration, torque drift ≤ ± 3% |
| Repeatability | Repeatability error≤±2% |
| Resolution | HC: 1×10-6(ppm)vol |
| CO: 0.01×10-2(%)vol | |
| CO2: 0.1×10-2(%)vol | |
| O2: 0.01×10-2(%)vol | |
| λ:0.01 | |
| Response Time | 95% response is not more than 10 seconds |
| Preheating Time | 8 minutes (preheating for 3 minutes for emergency detection) |
| Output Mode | Digital direct-reading display, a printer can be attached to print the gas name, maximum concentration, average value, test time, date, etc. Interface can be attached to connect with computer |
| Ambient Condition | Temperature: -5~50℃, relative humidity≤90% |
| Electricity | AC100-240V, 50/60Hz or DC12V (Optional power inverter) |
| Power Consumption | 40VA |
| External Dimension (L*W*H) | 420*310*170mm |
| Net Weight | 9kg |